CX1-3KVA Double conversion High frequency online UPS
Application:
CX1-3K series high frequency online UPS is specially designed for servers, data-center critical network devices, sensitive electronic equipment, telecom, bank, hospital, bureau, traffic, public security, ATM and so on.
Key Features:
♦ Advanced DSP numerical control technology application, the performance of UPS is more stable, more superior quality.
♦ The load power factor is 0.8
♦ Adopting digital control of active power factor correction technology, make the input power factor above 0.98, to avoid the pollution to power network, achieve energy saving, reduce the investment cost of the system.
♦ A very wide range of input voltage and frequency, even in remote parts of electric power environment is very bad to normal power supply, reduce the number of battery discharge, improve the service life of the battery.
♦ Can match generator to use, Input voltage and frequency range is wide, can effectively isolate the generator of electricity, to provide clean, safe and stable power supply load.
♦ Grid is not stable, UPS power supply mode conversion time is zero, effectively ensure the security and reliability of the load operation.
♦ Smart slot can provide abundant extensible function; can choose to install Winpower, SNMP card.
Specificaiton:
Model | CX1K | CX1KL |
Capacity | VA/W | 1000VA/800W | 1000VA/800W |
Input | Nominal Voltage | 200/208/220/230/240VAC |
Voltage Range | 115~300VAC |
Harmonic Distortion | <10% (Nonlinear load) |
Power Factor | 0.98 |
Frequency Range | 50Hz:46~54Hz; 60Hz:56~64Hz |
Output | Voltage | 200/208/220/230/240(1±1%)VAC |
Frequency | 50/60Hz (Adjustable); 50Hz AC Mode: Follow AC Mode (AC Range 46~54Hz); Battery Mode: 50Hz (1±0.2%) 60Hz AC Mode: Follow AC Mode (AC Range 56~64Hz); Battery Mode: 60Hz (1±0.2%) |
Wave Form | Pure sine wave |
Power Factor | 0.8 |
Harmonic Distortion | ≤4% (Linear load); ≤7% (Nonlinear load) |
Overload Capacity | 105%~150% 45S~25S; 150%~200% 25s~300ms; ≥200% 200ms |
Current Crest Ratio | 3:1 |
Connections | IEC320*4 |
Efficiency | Battery Mode | 81% |
AC Mode | 85% |
Battery | Type | Sealed free maintenance lead acid battery |
Nominal DC voltage | 24VDC | 36VDC |
Quantity | 12VDC×2 | 12VDC×3 |
Backup Time (Full Load) | >2.5min (Built in batteries12V7AH) | Depends on requested Back-up time |
Charge Current (Max) | 1A | 5A |
Charge Voltage (VDC) | 27.4V±0.2VDC | 41.1V±0.2VDC |
Recharge Time | 7 hours filling to 90% (standard) | Depends on external battery capacity (long-term) |
Bypass | Automatic Transfer | On overload and UPS failure |
Before UPS Power-on | Default ”ON” user adjustable to “YES” |
Transfer Time | | 0 ms; Less than 4ms from inverter to bypass and vice versa |
indicators | LCD Display | UPS status, Battery capacity, loading, Fault code (LCD: I/P &O/P voltage&frequency, Battery voltage) |
Audible | | Bypass, On battery mode, Battery low, Overload, Fault |
Acoustic Noise | At 1 Meter Distance | <45dB |
Communications | Intelligent RS232 serial port | Software support Windows family software, Linux, Sun network operating system, IBM Aix, Compaq True64 SGI IRIX, FreeBSD, HP-UX and MAC |
SNMP (Optional) | Remote control UPS through SNMP management and Internet |
USB (Optional) | Windows family software and Mac OS |
Environmental | Operating Temperature | 0~40℃ |
Operating Humidity | 20~90% (No condensing) |
Physical Parameter | L*W*H (mm) | 373*145*219 |
Net Weight (Kgs) | 9.5 | 5 |